Uninterruptible energy storage power supply configuration accessories

Time:2024-04-10 Views:1

  Uninterruptible energy storage power supply configuration accessories

  The UPS power system consists of five parts: the main circuit, bypass, battery and other power input circuit, rectifier (REC) for AC/DC conversion, inverter (INV) for DC/AC conversion, inverter and bypass output switching circuit and storage battery. The voltage regulation function of the system is usually completed by the rectifier, the rectifier device uses thyristor or high-frequency switching rectifier, itself has the function of controlling the output amplitude according to the change of the external power, so that when the external power changes (the change should meet the system requirements), the output amplitude is basically unchanged rectifier voltage. The purification function is completed by the energy storage battery, because the rectifier can not eliminate the instantaneous pulse interference, the voltage after rectification still has interference pulse. In addition to the function of storing direct DC energy, the energy storage battery is like connecting a large container capacitor to the rectifier, and the size of its equivalent capacitance is proportional to the capacity of the energy storage battery. Since the voltage at both ends of the capacitor cannot be mutated, that is, the smooth characteristics of the capacitor to the pulse are used to eliminate the pulse interference, and the purification function is played, also known as the shielding of interference. The frequency stability is completed by the converter, and the frequency stability depends on the stability of the oscillation frequency of the converter. In order to facilitate the daily operation and maintenance of the UPS power system, the system work switch, the automatic bypass switch after the host self-check fault, and the maintenance bypass switch are designed.

  When the power grid voltage is working normally, power supply the load, as shown in Figure 1-1, and charge the energy storage battery at the same time. When there is a sudden power failure, the UPS power supply starts to work, and the energy storage battery supplies the power required by the load to maintain normal production (as shown in black →). When the load is seriously overloaded due to production needs, the power grid voltage is directly supplied to the load through rectification

Read recommendations:

portabl station

5kw power wall

portable station power bank

Photovoltaic power generation for energy conservation, environmental protection, and stable power supply.power station portable solar Sale

portable solar power station Sale.Research status of superconducting energy storage in the United States.